LCA-4TR-50-1210-AP-156579, LCA-4TR-50-1210-AP-156579 Euchner, Đại lý Euchner tại Việt Nam

Controls and indicators

LED indicator yes 

Electrical connection ratings

Cascadable no
Current consumption 400 mA
Muting possible in combination with external sensors and an evaluation unit
Operating voltage DC 24 V DC -20% ... +20%
Receiver power consumption 2 W
Transmitter power consumption 1 W

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection Plug connector M12 (5-pin transmitter/8-pin receiver)
Degree of protection IP65/IP67
Dimensions 28x30 mm 
Height of the protective field 1210 mm
Height of the sensor 1263 mm
Installation orientation any 
maximum length of connecting cables 100 m
Number of safety outputs 2 static, self-monitoring PNP safety outputs 
Range of the protective field 20000 mm
Reaction time 6 ms
Resolution 50 mm

Reliability values according to EN ISO 13849-1

ESPE type
Mission time 20 y
Performance Level PL e 
PFHd 1.41x10-8
Safety Integrity Level SIL 3 / SILCL 3